How-to guide

Keep benign values out of indicators

Stop OpenCTI from creating indicators for benign values, such as your own IP ranges or popular domains, with exclusion lists that apply to every source.

OpenCTIFor administrators and CTI analysts

An exclusion list holds values you know to be legitimate, such as your own address ranges, your domains or well-known services. OpenCTI refuses to create an indicator whose STIX pattern contains one of these values, whatever the source. This page shows how to create a list, check that every platform node uses it, and keep it up to date.

Before you start

  • Your role has the Manage customization capability.
  • Your values are in a plain text file (.txt) with one value per line, or ready to paste. A file is limited to 10 MB by default (app:exclusion_list:file_max_size, see Functional customization in the configuration reference).
  • Each list holds one family of types: IP addresses (IPv4 address, IPv6 address), or the other observable types. A list cannot mix both.

How values match

TypeWrite values asMatches
IPv4 address, IPv6 addressAn address, 192.168.20.10, or a CIDR range, 192.168.0.0/16The address, or every address in the range
Domain nameA name, example.com, or a name that starts with a dot, .example.comThe exact name. With a leading dot, every subdomain, such as www.example.com and booking.eu.example.com, but not example.com itself: list both values to cover the name and its subdomains
URLA full URL, https://www.example.com/login, or its end from a dot, .example.comThe exact URL. With a leading dot, a URL that ends with that value: .example.com matches https://www.example.com but not https://www.example.com/login
File, ArtifactA hash, such as a SHA-256A pattern that contains one of the hashes in the list
Hostname, Email addressThe valueThe exact value

Write values in the case your sources use, in practice lowercase for domains and hashes: a value in another case is not reliably matched.

Create an exclusion list

  1. Open Settings, then Customization, then Exclusion lists and click Create Exclusion List. The Create an exclusion list panel opens.
  2. Enter a Name and a Description that says where the values come from.
  3. In Apply on indicator observable types, choose the types the values belong to. Choosing an IP type with another type shows Incompatible types, can't mix IP types with other types.
  4. Add the values. Upload file is on: select your .txt file under Associated file. To type the values instead, turn Upload file off and paste them in Content (1 / line).
  5. Click Create. The list appears in the table, active, with its types in the Entity type column.
OpenCTI 7.261119.0
ExampleNever flag the member network as malicious

The feeds Example CERT ingests sometimes report private addresses seen in sandbox runs, and a detection tool that receives [ipv4-addr:value = '10.20.30.40'] would alert on the hotel members' own network.

  • Name: Internal ranges
  • Description: Private address space of the member network
  • Apply on indicator observable types: IPv4 address and IPv6 address
  • Upload file: on, with the file internal-ranges.txt in Associated file:
10.0.0.0/8
172.16.0.0/12
192.168.0.0/16
fd00::/8

Once Status reads Synchronized, a feed that sends an indicator for 10.20.30.40 gets the error Indicator of type stix is contained in exclusion list. and nothing is created. The member domains go in a second list, Trusted domains, applied on Domain name, with example.com and .example.com to cover the domain and every subdomain; URLs on those domains need their own values, because a leading dot only matches a URL without a path. The file limit stays at its default; to accept larger files, raise app:exclusion_list:file_max_size:

services:
  opencti:
    environment:
      APP__EXCLUSION_LIST__FILE_MAX_SIZE: 20000000

Check that the list is applied

OpenCTI copies the lists to a cache on every platform node. The cards above the table show where that stands:

  • Status reads In progress while the nodes load the change, then Synchronized.
  • Last modification date is the last change to any list; Current cache version date is the version every node uses. When both dates match, every node applies your list.
OpenCTI 7.261119.0

The table also gives each list's Number of elements, Creation date and whether it is Active.

Keep a list up to date

Open the row menu of a list:

  • Update opens the Update an exclusion list panel to change the name, description, types or values. You can edit the values in place when the file is under 1 MB; for a larger list, turn on Upload file and send a new file, which replaces the old one.
  • Disable pauses the list without deleting it; Enable turns it back on.
  • Download file gives you the current values as a text file.
  • Delete removes the list.

Every change starts a new synchronization: wait for Synchronized before you rely on it.

What gets excluded

When a connector, a feed (CSV, JSON, RSS, TAXII), a playbook or a user creates an indicator, OpenCTI extracts the observable values from its STIX pattern. If one of them is in an active list, the indicator is not created and the source receives the error Indicator of type stix is contained in exclusion list.

Note

Exclusion lists apply to indicators with a STIX pattern only. An observable created on its own, for example by a feed that does not create indicators, is not filtered. Indicators already in the platform stay as they are.

What's next

NextRepair data after an upgrade
OpenCTI
Cyber threat intelligence as a knowledge graph: ingest, analyze, automate, share.

Published

Overview